Ebpay生命医药出版社

Ebpay生命

100530

论文已发表

提 交 论 文


注册即可获取Ebpay生命的最新动态

注 册



IF 收录期刊



  • 3.3 Breast Cancer (Dove Med Press)
  • 3.4 Clin Epidemiol
  • 2.5 Cancer Manag Res
  • 2.9 Infect Drug Resist
  • 3.5 Clin Interv Aging
  • 4.7 Drug Des Dev Ther
  • 2.7 Int J Chronic Obstr
  • 6.6 Int J Nanomed
  • 2.5 Int J Women's Health
  • 2.5 Neuropsych Dis Treat
  • 2.7 OncoTargets Ther
  • 2.0 Patient Prefer Adher
  • 2.3 Ther Clin Risk Manag
  • 2.5 J Pain Res
  • 2.8 Diabet Metab Synd Ob
  • 2.8 Psychol Res Behav Ma
  • 3.0 Nat Sci Sleep
  • 1.8 Pharmgenomics Pers Med
  • 2.7 Risk Manag Healthc Policy
  • 4.2 J Inflamm Res
  • 2.1 Int J Gen Med
  • 4.2 J Hepatocell Carcinoma
  • 3.7 J Asthma Allergy
  • 1.9 Clin Cosmet Investig Dermatol
  • 2.7 J Multidiscip Healthc



更多详情 >>





视频

Comparisons of clinically based outcome measures and laboratory-based outcome measure for balance in patients following total hip and knee arthroplasty

 

Authors Jogi P, Overend TJ, Kramer J

Received 24 October 2016

Accepted for publication 26 January 2017

Published 10 April 2017 Volume 2017:9 Pages 23—33

DOI http://doi.org/10.2147/ORR.S125581

Checked for plagiarism Yes

Review by Single-blind

Peer reviewers approved by Dr Amy Norman

Peer reviewer comments 3

Editor who approved publication: Professor Clark Hung

Background: Information available in the literature on clinically based and laboratory-based outcome measures of balance is limited. How much information is provided by clinically based outcome measures compared to laboratory-based measure in patients with total hip (THA) and knee arthroplasty (TKA) is not known.
Aim: The purpose of this study was to determine the relationship between selected clinically based outcome measures and laboratory-based force platform measure in patients following THA and TKA.
Methods: Patients who underwent THA (n = 26) and TKA (n = 28) were evaluated at about 5–7 weeks following surgery. Participants were assessed using four clinically based outcome measures – 1) the Berg Balance Scale (BBS), 2) the Timed Up and Go test (TUG), 3) the Activities-specific Balance Confidence Scale (ABC), and 4) the Western Ontario McMaster Universities Osteoarthritis Index-function subscale (WOMAC-function) – and one laboratory-based force plate measure (95% ellipse area).
Results: Moderate correlations were observed between the BBS and the 95% ellipse area of force plate (r = 0.46–0.51) for the two-legged stance, the anterior lean stance, and the posterior lean stance. Fair correlations were observed between TUG and the 95% ellipse area of force plate (r = 0.31–0.37) for all the three test conditions. Low correlations were observed for the ABC and the WOMAC-function with the 95% ellipse area of force plate (r = 0.11–0.25) for all the three test conditions.
Conclusion: The BBS demonstrated the greatest correlations with the 95% ellipse area of the force plate measure and should be preferred by physical therapists over the TUG, the ABC, and the WOMAC-function to assess balance in patients with THA and TKA.
Keywords: total knee arthroplasty, total hip arthroplasty, force plate, clinical measures, balance

 

摘要视频链接:Comparison of clinical and laboratory measures





Download Article[PDF]