视频

The effect of increasing power when grooving using phacoemulsification

 

Authors Thomson RS, Bird BA, Stutz LA, Heczko JB, Bernhisel AA, Barlow WR, Zaugg B, Olson RJ, Pettey JH

Received 16 November 2018

Accepted for publication 14 January 2019

Published 12 April 2019 Volume 2019:13 Pages 611—615

DOI http://doi.org/10.2147/OPTH.S194731

Checked for plagiarism Yes

Review by Single-blind

Peer reviewers approved by Ms Justinn Cochran

Peer reviewer comments 3

Editor who approved publication: Dr Scott Fraser

Purpose: To determine optimal power settings on the Centurion Vision System during the grooving step in cataract surgery.
Methods: Intact porcine lenses hardened by formalin and placed in a chamber designed to simulate the anterior chamber of the eye were used to test longitudinal power at 40%, 70%, and 100% and torsional power at 0%. Flow rate was set at 40 mL/min. Vacuum was set at 400 mmHg, intraocular pressure was set at 50 mmHg, and a balanced phacoemulsification tip with a 20 degree tip and a 30 degree bevel was used. Efficiency (time to groove the lens in half) was determined.
Results: Increasing longitudinal power from 40% to 70% increased efficiency by 28% (<0.05), and by 32% (<0.05) when increasing longitudinal power from 40% to 100%. There was no statistically significant increase in efficiency from 70% to 100%.
Conclusion: For the tested variables, a longitudinal power of 70% was determined to be most efficient during the grooving step of cataract surgery for equivalent 3–4+ nuclei. Further increases in power demonstrated no statistically significant improvement in efficiency.
Keywords: settings, longitudinal power, efficiency, porcine lens model


 

摘要视频链接:Settings for nucleus grooving




 

Download Article[PDF]